亚洲色大18成人网站www在线播放_精品久久久久久亚洲偷窥一区_欧美精品18videosex性欧美_播放孕妇在线观看免费_亚洲成av人片高潮喷水_www视频在线观看网站_久久一日本道色综合久久大香_真人高清实拍女处被破的视频_狠狠亚洲婷婷综合色香五月排名

Ladder flat bottom test block -10 Ladder - non-destructive testing ultrasonic test block

According to the NDT standard of pressure equipment NB/T47013-2015, the stepped flat test block is suitable for using twin straight probe to detect the thickness of the plate less than 20mm, and can also be used to make the distance-amplitude characteristic curve of the twin probe.

According to the NDT standard of pressure equipment NB/T47013-2015, the stepped flat test block is suitable for using twin straight probe to detect the thickness of the plate less than 20mm, and can also be used to make the distance-amplitude characteristic curve of the twin probe.探傷試塊


Test method: (1) Select a step with the thickness of the test plate or greater than the thickness of the test plate, place the probe on the selected step, adjust the instrument is the first bottom wave adjusted to 50% of the full scale, increase 10dB, as the reference sensitivity, and then gain 6dB on the basis of the reference sensitivity as the detection sensitivity.



(2) The test block can also be used to make the distance-amplitude characteristic curve of the twin probe. Select the verified straight probe and place it in position a in Diagram 1. Move the probe back and forth to get the maximum reflection echo on the plane of the direct sound beam. Adjust the echo amplitude to 50% of the full screen height, record the dB value at this time, which is the first point. The probe is placed at position b in Diagram 1, and the probe is moved backwards and forwards to the left and right so that the direct sound beam can get the maximum reflected echo on the plane. Adjust the echo amplitude to 50% of the full screen height, record the dB value at this time, which is the second point. The probe is placed at position c in Diagram 1, and the probe is moved backwards and forwards to the left and right so that the direct sound beam can get the maximum reflected echo on the plane. Adjust the echo amplitude to 50% of the height of the full screen and record the dB value at this time, which is the third point. By analogy, all points within the effective detection range of the probe are recorded, and the above points are connected into a curve, which is the distance amplitude characteristic curve of the twin-crystal straight probe specified in the standard.


探傷試塊探傷試塊



Online purchase:www.ndtmall.cn